Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22.111
Filtrar
2.
Tech Coloproctol ; 28(1): 45, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38568325

RESUMO

BACKGROUND: Faecal incontinence (FI) is common, with a significant impact on quality of life. Percutaneous tibial nerve stimulation (PTNS) is a therapy for FI; however, its role has recently been questioned. Here we report the short-term clinical and manometric outcomes in a large tertiary centre. METHODS: A retrospective review of a prospective PTNS database was performed, extracting patient-reported FI outcome measures including bowel diary, the St Marks's Incontinence Score (SMIS) and Manchester Health Questionnaire (MHQ). Successful treatment was > 50% improvement in symptoms, whilst a partial response was 25-50% improvement. High-resolution anorectal manometry (HRAM) results before and after PTNS were recorded. RESULTS: Data were available from 135 patients [119 (88%) females; median age: 60 years (range: 27-82years)]. Overall, patients reported a reduction in urge FI (2.5-1) and passive FI episodes (2-1.5; p < 0.05) alongside a reduction in SMIS (16.5-14) and MHQ (517.5-460.0; p < 0.001). Some 76 (56%) patients reported success, whilst a further 20 (15%) reported a partial response. There were statistically significant reductions in rectal balloon thresholds and an increase in incremental squeeze pressure; however, these changes were independent of treatment success. CONCLUSION: Patients report PTNS improves FI symptoms in the short term. Despite this improvement, changes in HRAM parameters were independent of this success. HRAM may be unable to measure the clinical effect of PTNS, or there remains the possibility of a placebo effect. Further work is required to define the role of PTNS in the treatment of FI.


Assuntos
Incontinência Fecal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Incontinência Fecal/terapia , Manometria , Estudos Prospectivos , Qualidade de Vida , Nervo Tibial , Adulto , Idoso , Idoso de 80 Anos ou mais
3.
BMC Gastroenterol ; 24(1): 127, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575859

RESUMO

BACKGROUND/AIM: London Protocol (LP) and Classification allied to high-resolution manometry (HRM) technological evolution has updated and enhanced the diagnostic armamentarium in anorectal disorders. This study aims to evaluate LP reproducibility under water-perfused HRM, provide normal data and new parameters based on 3D and healthy comparison studies under perfusional HRM. METHODS: Fifty healthy (25 F) underwent water-perfused 36 channel HRM based on LP at resting, squeeze, cough, push, and rectal sensory. Additional 3D manometric parameters were: pressure-volume (PV) 104mmHg2.cm (resting, short and long squeeze, cough); highest and lowest pressure asymmetry (resting, short squeeze, and cough). Complementary parameters (CP) were: resting (mean pressure, functional anal canal length); short squeeze (mean and maximum absolute squeeze pressure), endurance (fatigue rate, fatigue rate index, capacity to sustain); cough (anorectal gradient pressure); push (rectum-anal gradient pressure, anal canal relaxation percent); recto-anal inhibitory reflex (anal canal relaxation percent). RESULTS: No difference to genders: resting (LP, CP, and 3D); short squeeze (highest pressure asymmetry); endurance (CP); cough (CP, highest and lowest pressure asymmetry); push (gradient pressure); rectal sensory. Higher pressure in men: short squeeze (maximum incremental, absolute, and mean pressure, PV, lowest pressure asymmetry); long squeeze (PV); cough (anal canal and rectum maximum pressure, anal canal PV); push (anal canal and rectum maximum pressure). Anal canal relaxation was higher in women (push). CONCLUSIONS: LP reproducibility is feasible under water-perfused HRM, and comparative studies could bring similarity to dataset expansion. Novel 3D parameters need further studies with healthy and larger data to be validated and for disease comparisons. KEY POINTS: • London Protocol and Classification allied with the technological evolution of HRM (software and probes) has refined the diagnostic armamentarium in anorectal disorders. • Novel 3D and deepening the analysis of manometric parameters before the London Classification as a contributory diagnostic tool. • Comparison of healthy volunteers according to the London Protocol under a perfusional high-resolution system could establish equivalence points.


Assuntos
Incontinência Fecal , Doenças Retais , Humanos , Feminino , Masculino , Pressão , Reprodutibilidade dos Testes , Londres , Doenças Retais/diagnóstico , Manometria/métodos , Reto , Canal Anal , Tosse
4.
Ger Med Sci ; 22: Doc03, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38651019

RESUMO

Introduction: Rhinophonia aperta may result from velopharyngeal insufficiency. Neuromuscular electrical stimulation (NMES) has been discussed in the context of muscle strengthening. The aim of this study was to evaluate in healthy subjects whether NMES can change the velopharyngeal closure pattern during phonation and increase muscle strength. Method: Eleven healthy adult volunteers (21-57 years) were included. Pressure profiles were measured by high resolution manometry (HRM): isolated sustained articulation of /a/ over 5 s (protocol 1), isolated NMES applied to soft palate above motor threshold (protocol 2) and combined articulation with NMES (protocol 3). Mean activation pressures (MeanAct), maximum pressures (Max), Area under curve (AUC) and type of velum reactions were compared. A statistical comparison of mean values of protocol 1 versus protocol 3 was carried out using the Wilcoxon signed rank test. Ordinally scaled parameters were analyzed by cross table. Results: MeanAct values measured: 17.15±20.69 mmHg (protocol 1), 34.59±25.75 mmHg (protocol 3) on average, Max: 37.86±49.17 mmHg (protocol 1), 87.24±59.53 mmHg (protocol 3) and AUC: 17.06±20.70 mmHg.s (protocol 1), 33.76±23.81 mmHg.s (protocol 3). Protocol 2 produced velum reactions on 32 occasions. These presented with MeanAct values of 13.58±12.40 mmHg, Max values of 56.14±53.14 mmHg and AUC values of 13.84±12.78 mmHg.s on average. Statistical analysis comparing protocol 1 and 3 showed more positive ranks for MeanAct, Max and AUC. This difference reached statistical significance (p=0.026) for maximum pressure values. Conclusions: NMES in combination with articulation results in a change of the velopharyngeal closure pattern with a pressure increase of around 200% in healthy individuals. This might be of therapeutic benefit for patients with velopharyngeal insufficiency.


Assuntos
Fonação , Pressão , Humanos , Adulto , Masculino , Feminino , Fonação/fisiologia , Adulto Jovem , Pessoa de Meia-Idade , Palato Mole/fisiologia , Terapia por Estimulação Elétrica/métodos , Manometria/métodos , Insuficiência Velofaríngea/fisiopatologia , Força Muscular/fisiologia , Voluntários Saudáveis
5.
Ger Med Sci ; 22: Doc02, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38651020

RESUMO

Background: During articulation the velopharynx needs to be opened and closed rapidly and a tight closure is needed. Based on the hypothesis that patients with cleft lip and palate (CLP) produce lower pressures in the velopharynx than healthy individuals, this study compared pressure profiles of the velopharyngeal closure during articulation of different sounds between healthy participants and patients with surgically closed unilateral CLP (UCLP) using high resolution manometry (HRM). Materials and methods: Ten healthy adult volunteers (group 1: 20-25.5 years) and ten patients with a non-syndromic surgically reconstructed UCLP (group 2: 19.1-26.9 years) were included in this study. Pressure profiles during the articulation of four sounds (/i:/, /s/, /ʃ/ and /n/) were measured by HRM. Maximum, minimum and average pressures, time intervals as well as detection of a previously described 3-phase-model were compared. Results: Both groups presented with similar pressure curves for each phoneme with regards to the phases described and pressure peaks, but differed in total pressures. An exception was noted for the sound /i:/, where a 3-phase-model could not be seen for most patients with UCLP. Differences in velopharynx pressures of 50% and more were found between the two groups. Maximum and average pressures in the production of the alveolar fricative reached statistical significance. Conclusions: It can be concluded that velopharyngeal pressures of patients with UCLP are not sufficient to eliminate nasal resonance or turbulence during articulation, especially for more complex sounds. These results support a general understanding of hypernasality during speech implying a (relative) velopharyngeal insufficiency.


Assuntos
Fenda Labial , Fissura Palatina , Pressão , Humanos , Fissura Palatina/fisiopatologia , Fissura Palatina/complicações , Fissura Palatina/cirurgia , Fenda Labial/fisiopatologia , Fenda Labial/complicações , Fenda Labial/cirurgia , Masculino , Adulto , Feminino , Adulto Jovem , Manometria/métodos , Fonética , Insuficiência Velofaríngea/fisiopatologia , Insuficiência Velofaríngea/etiologia , Faringe/fisiopatologia , Estudos de Casos e Controles
6.
Med J Malaysia ; 79(2): 206-211, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38553928

RESUMO

INTRODUCTION: Numerous tonometers are available to measure intraocular pressure (IOP) in children with glaucoma. This review aims to discuss IOP measurement techniques and principles and compare the accuracy, tolerability and ease of use of available tonometers in measuring IOP in paediatric glaucoma patients. MATERIALS AND METHODS: A review of observational studies was conducted to discuss the accuracy, tolerability and ease of use of tonometers in measuring IOP in children with glaucoma. RESULTS: Goldmann applanation tonometry (GAT) and its portable handheld versions remain the gold standard in measuring IOP. Tono-Pen (Reichert Ophthalmic Instruments, Depew, New York, USA) and rebound tonometer (RBT) both correlate well with GAT. Although both tonometers tend to overestimate IOP, Tono-Pen overestimates more than RBT. Overestimation is more remarkable in higher IOP and corneal pathologies (such as but not limited to scarred cornea and denser corneal opacity). RBT was better tolerated than other tonometers in children and was easier to use in children of all ages. CONCLUSIONS: RBT is the preferred tonometer for measuring IOP in children with glaucoma, as it is less traumatic, time efficient and does not require fluorescein dye or anaesthesia. However, examiners should use a second tonometer to confirm elevated IOP readings from the RBT.


Assuntos
Glaucoma , Pressão Intraocular , Criança , Humanos , Glaucoma/diagnóstico , Tonometria Ocular/métodos , Córnea , Manometria , Reprodutibilidade dos Testes
7.
J Gastrointestin Liver Dis ; 33(1): 15, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38554412

RESUMO

A 57-year-old man presented with dysphagia in solids and liquids deteriorating in the last months and weight loss of 3 kg. A thoracic CT revealed a limit dilatation of the lower esophagus with food residue. An upper endoscopy was performed revealing bubble content and a contraction of the Lower Esophageal Sphincter (LES). A barium esophagogram demonstrated deceleration of esophageal emptying and a bird beak sign indicative of esophageal achalasia (Figure A). High resolution esophageal manometry was performed to evaluate the subtype of achalasia. The catheter could not be intubated into the stomach because of LES spasticity, it folded back cephalad at this level, producing a mirror image, the characteristic "butterfly wings" appearance of a folded manometry catheter (Figure B).


Assuntos
Acalasia Esofágica , Masculino , Humanos , Pessoa de Meia-Idade , Acalasia Esofágica/complicações , Acalasia Esofágica/diagnóstico , Radiografia , Esfíncter Esofágico Inferior , Manometria , Trânsito Gastrointestinal
8.
Dig Dis Sci ; 69(4): 1302-1317, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38430328

RESUMO

BACKGROUND/AIMS: Patients with chronic constipation (CC) exhibit symptoms and functional abnormalities upon testing, but their relationship to age and gender is unclear. We assessed age- and gender-related differences in symptoms, colon transit time, and anorectal motility, sensation, and expulsion. PATIENTS AND METHODS: Retrospective, post hoc data analysis of patients with CC, who underwent Wireless Motility Capsule (WMC), High-Resolution Anorectal Manometry (HR-ARM), Balloon Expulsion Test (BET) and Rectal Sensory Testing (RST). Clinical assessment was made by questionnaires. Standard WMC criteria for colonic transit time (CTT) and the London classification was used for HR-ARM analyses, and regression plots between age, gender, CTT, HR-HRM, RST and BET were calculated. RESULTS: We studied 75 women and 91 men. Abdominal pain, infrequent defecation, incomplete evacuation, defecatory straining, and multiple motility and anorectal function abnormalities were common. Abdominal pain was least frequently, and straining was most frequently associated with a motility abnormality. For each symptom, the highest prevalence was associated with failed BET. There was a significant increase in CTT with age only in men (p = 0.0006). In men, for each year of age there was a CTT increase of 1.02 h. The prevalence of abdominal pain and incomplete evacuation for females was significantly higher than that for males (both P < 0.05). The prevalence of low anal squeeze pressure for females was significantly higher than that for males, and the prevalence of poor rectal sensation for males was significantly higher than that for females (both P < 0.05). A significant decrease in basal anal and squeeze pressures with age occurred in women (p < 0.0001); an increase in age of one year was associated with a decrease in anal base pressure of 1.2 mmHg. Abnormal CTT and HR-ARM tests were associated with increased symptom frequency, but not severity. CONCLUSIONS: There are significant age- and gender-related differences in symptoms, CTT, and HR-HRM parameters, rectal sensation, and expulsion, that may influence the multifaceted management of constipation.


Assuntos
Constipação Intestinal , Defecação , Masculino , Humanos , Feminino , Estudos Retrospectivos , Manometria/métodos , Reto , Canal Anal , Dor Abdominal
9.
Eur J Gastroenterol Hepatol ; 36(5): 534-544, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555600

RESUMO

This study aims to compare the diagnostic value of balloon expulsion test and anorectal manometry in patients with constipation through meta-analysis. Databases, encompassing PubMed, EMBASE, Cochrane Library, Web of Science, etc. were searched for all English publications on the diagnosis of constipation using balloon expulsion test and anorectal manometry. The publication date was restricted from the inception of the databases until December 2022. Data analysis was carried out utilizing Stata 15.0 and Meta-Disc 1.4 software. Thirteen studies involving 2171 patients with constipation were included. According to the meta-analysis, the balloon expulsion test showed a pooled sensitivity of 0.75 (95% CI: 0.72-0.77), a pooled specificity (Spe) of 0.67 (95% CI: 0.62-0.72), a pooled positive likelihood ratio (+LR) of 3.24 (95% CI: 1.53-6.88), a pooled negative likelihood ratio (-LR) 0.35 (95% CI: 0.23-0.52) and a pooled diagnostic odds ratio (DOR) of 9.47 (95% CI: 3.27-27.44). For anorectal manometry, the pooled Sen, Spe, +LR, -LR and DOR were 0.74 (95% CI: 0.72-0.76), 0.73 (95% CI: 0.70-0.76), 2.69 (95% CI: 2.18-3.32), 0.35 (95% CI: 0.28-0.43), and 8.3 (95% CI: 5.4-12.75), respectively. The area under the summary receiver operating characteristic curve areas for balloon expulsion test and anorectal manometry were 0.8123 and 0.8088, respectively, with no statistically significant disparity (Z = -0.113, P > 0.05). Both the balloon expulsion test and anorectal manometry demonstrate comparable diagnostic performance, each offering unique advantages. These diagnostic procedures hold significance in the diagnosis of constipation.


Assuntos
Constipação Intestinal , Humanos , Manometria/métodos , Constipação Intestinal/diagnóstico , Curva ROC , Sensibilidade e Especificidade
11.
Gastroenterol. hepatol. (Ed. impr.) ; 47(3): 272-285, mar. 2024. ilus, graf
Artigo em Espanhol | IBECS | ID: ibc-231212

RESUMO

La disfagia orofaríngea (DO) es una enfermedad con una alta prevalencia en diferentes fenotipos de pacientes. La manometría de alta resolución faringoesofágica (MARFE) con impedancia (MARFE-I) se ha convertido en los últimos años en una técnica fundamental para el mejor entendimiento de la fisiopatología de las disfunciones de la faringe y del esfínter esofágico superior (EES) en pacientes con DO. Diversos grupos de expertos han propuesto una metodología para la práctica de la MARFE-I y para la estandarización de las diferentes métricas para el estudio de las disfunciones de la motilidad faríngea y del EES basadas en el la cuantificación de 3fenómenos principales: la relajación del EES, la resistencia al flujo a través del EES y la propulsión del bolo a través de la faringe hacia el esófago. De acuerdo a las alteraciones de estas métricas, se proponen 3patrones de disfunción que permiten un abordaje terapéutico específico: a) restricción al flujo del EES con propulsión faríngea normal; b) restricción al flujo del EES con propulsión faríngea inefectiva, y c) contracción faríngea inefectiva con normal relajación del EES. Presentamos una revisión práctica de la metodología y la métrica que emplean los principales grupos de trabajo junto con la descripción de los principales patrones de disfunción de acuerdo con nuestra experiencia para poner de relevancia la utilidad de la MARFE-I en el estudio de la fisiopatología y selección de un tratamiento específico en pacientes con DO. (AU)


Oropharyngeal dysphagia (OD) is a pathology with a high prevalence in different patient phenotypes. High-resolution pharyngoesophageal manometry (HRPM) with impedance (HRPM-I) has become in recent years a fundamental technique for better understanding the pathophysiology of pharynx and upper oesophageal sphincter (UES) dysfunctions in patients with OD. Various groups of experts have proposed a methodology for the practice of the HRPM-I and for the standardization of the different metrics for the study of pharyngeal motility and UES dysfunctions based on the quantification of 3main phenomena: relaxation of the UES, resistance to flow through the UES and propulsion of the bolo through the pharynx into the oesophagus. According to the alterations of these metrics, 3patterns of dysfunction are proposed that allow a specific therapeutic approach: (a) UES flow restriction with normal pharyngeal propulsión; (b) UES flow restriction with ineffective pharyngeal propulsion, and (c) ineffective pharyngeal contraction with normal relaxation of the UES. We present a practical review of the methodology and metrics used by the main working groups together with the description of the main patterns of dysfunction according to our experience to highlight the usefulness of the HRPM-I in the study of the pathophysiology and selection of a specific treatment in patients with OD. (AU)


Assuntos
Transtornos de Deglutição/fisiopatologia , Manometria , Esfíncter Esofágico Superior/fisiopatologia
13.
J Pediatr Gastroenterol Nutr ; 78(4): 783-789, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38314945

RESUMO

OBJECTIVES: Pharyngeal contractile integral (PhCI) is the product of mean pharyngeal contractile amplitude, length, and duration, and provides a single metric for the vigor of entire pharyngeal contraction. A major limitation in children is lack of characterization of PhCI on high-resolution pharyngeal manometry. We aimed to determine and compare the values of PhCI in children with the abnormal and normal videofluoroscopic study of swallow (VFSS). METHODS: Children who underwent high-resolution pharyngeal and esophageal manometry (HRPM/HREM), as well as VFSS, were divided into two groups; "normal VFSS" and "abnormal VFSS" groups. PhCI was calculated from the pharyngo-esophageal manometry analysis software (MMS, v9.5, Laborie Medical Technologies), and compared in these two groups. RESULTS: Of 67 children, 9 had abnormal VFSS (mean age 64 ± 50 months; 66.7% males), while 58 had normal VFSS (mean age 123 ± 55 months; 47% males). The mean PhCI in abnormal and normal VFSS groups was 82.00 ± 51.90 and 147.28 ± 53.89 mmHg.s.cm, respectively (p = 0.001). Subjects with abnormal VFSS were significantly younger than those with normal VFSS (p = 0.003). However, after adjusting for the VFSS result, age was no longer related to PhCI (p = 0.364). In subgroup analysis of children presenting with dysphagia, the mean PhCI in abnormal (9 subjects) and normal (36 subjects) VFSS groups was 82.00 ± 51.90 and 141.86 ± 50.39 mmHg.s.cm, respectively (p = 0.003). CONCLUSIONS: PhCI was significantly lower in children with abnormal VFSS than in those with normal VFSS. We did not find a significant impact of age on PhCI in our pediatric populations.


Assuntos
Transtornos de Deglutição , Deglutição , Masculino , Criança , Humanos , Lactente , Pré-Escolar , Feminino , Faringe/diagnóstico por imagem , Manometria , Contração Muscular
16.
Curr Gastroenterol Rep ; 26(4): 115-123, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38324172

RESUMO

PURPOSE OF REVIEW: Artificial intelligence (AI) is a broad term that pertains to a computer's ability to mimic and sometimes surpass human intelligence in interpretation of large datasets. The adoption of AI in gastrointestinal motility has been slower compared to other areas such as polyp detection and interpretation of histopathology. RECENT FINDINGS: Within esophageal physiologic testing, AI can automate interpretation of image-based tests, especially high resolution manometry (HRM) and functional luminal imaging probe (FLIP) studies. Basic tasks such as identification of landmarks, determining adequacy of the HRM study and identification from achalasia from non-achalasia patterns are achieved with good accuracy. However, existing AI systems compare AI interpretation to expert analysis rather than to clinical outcome from management based on AI diagnosis. The use of AI methods is much less advanced within the field of ambulatory reflux monitoring, where challenges exist in assimilation of data from multiple impedance and pH channels. There remains potential for replication of the AI successes within esophageal physiologic testing to HRM of the anorectum, and to innovative and novel methods of evaluating gastric electrical activity and motor function. The use of AI has tremendous potential to improve detection of dysmotility within the esophagus using esophageal physiologic testing, as well as in other regions of the gastrointestinal tract. Eventually, integration of patient presentation, demographics and alternate test results to individual motility test interpretation will improve diagnostic precision and prognostication using AI tools.


Assuntos
Acalasia Esofágica , Transtornos da Motilidade Esofágica , Humanos , Inteligência Artificial , Transtornos da Motilidade Esofágica/diagnóstico , Acalasia Esofágica/diagnóstico , Manometria/métodos
17.
Comput Methods Programs Biomed ; 247: 108082, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38422893

RESUMO

BACKGROUND AND OBJECTIVE: Aortic blood pressure (ABP) is a more effective prognostic indicator of cardiovascular disease than peripheral blood pressure. A highly accurate algorithm for non-invasively deriving the ABP wave, based on ultrasonic measurement of aortic flow combined with peripheral pulse wave measurements, has been proposed elsewhere. However, it has remained at the proof-of-concept stage because it requires a priori knowledge of the ABP waveform to calculate aortic pulse wave velocity (PWV). The objective of this study is to transform this proof-of-concept algorithm into a clinically feasible technique. METHODS: We used the Bramwell-Hill equation to non-invasively calculate aortic PWV which was then used to reconstruct the ABP waveform from non-invasively determined aortic blood flow velocity, aortic diameter, and radial pressure. The two aortic variables were acquired by an ultrasound system from 90 subjects, followed by recordings of radial pressure using a SphygmoCor device. The ABPs estimated by the new algorithm were compared with reference values obtained by cardiac catheterization (invasive validation, 8 subjects aged 62.3 ± 12.7 years) and a SphygmoCor device (non-invasive validation, 82 subjects aged 45.0 ± 17.8 years). RESULTS: In the invasive comparison, there was good agreement between the estimated and directly measured pressures: the mean error in systolic blood pressure (SBP) was 1.4 ± 0.8 mmHg; diastolic blood pressure (DBP), 0.9 ± 0.8 mmHg; mean blood pressure (MBP), 1.8 ± 1.2 mmHg and pulse pressure (PP), 1.4 ± 1.1 mmHg. In the non-invasive comparison, the estimated and directly measured pressures also agreed well: the errors being: SBP, 2.0 ± 1.4 mmHg; DBP, 0.8 ± 0.1 mmHg; MBP, 0.1 ± 0.1 mmHg and PP, 2.3 ± 1.6 mmHg. The significance of the differences in mean errors between calculated and reference values for SBP, DBP, MBP and PP were assessed by paired t-tests. The agreement between the reference methods and those obtained by applying the new approach was also expressed by correlation and Bland-Altman plots. CONCLUSION: The new method proposed here can accurately estimate ABP, allowing this important variable to be obtained non-invasively, using standard, well validated measurement techniques. It thus has the potential to relocate ABP estimation from a research environment to more routine use in the cardiac clinic. SHORT ABSTRACT: A highly accurate algorithm for non-invasively deriving the ABP wave has been proposed elsewhere. However, it has remained at the proof-of-concept stage because it requires a priori knowledge of the ABP waveform to calculate aortic pulse wave velocity (PWV). This study aims to transform this proof-of-concept algorithm into a clinically feasible technique. We used the Bramwell-Hill equation to non-invasively calculate aortic PWV which was then used to reconstruct the ABP waveform. The ABPs estimated by the new algorithm were compared with reference values obtained by cardiac catheterization or a SphygmoCor device. The results showed that there was good agreement between the estimated and directly measured pressures. The new method proposed can accurately estimate ABP, allowing this important variable to be obtained non-invasively, using standard, well validated measurement techniques. It thus has the potential to relocate ABP estimation from a research environment to more routine use in the cardiac clinic.


Assuntos
Pressão Arterial , Análise de Onda de Pulso , Humanos , Pressão Arterial/fisiologia , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial , Manometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...